Extraction, chromatographic and mass spectrometric methods for lipid analysis

Lipids make up a diverse subset of biomolecules that are responsible for mediating a variety of structural and functional properties as well as modulating cellular functions such as trafficking, regulation of membrane proteins and subcellular compartmentalization. In particular, phospholipids are the main constituents of biological membranes and play major roles in cellular processes like transmembrane signaling and structural dynamics. The chemical and structural variety of lipids makes analysis using a single experimental approach quite challenging. Research in the field relies on the use of multiple techniques to detect and quantify components of cellular lipidomes as well as determine structural features and cellular organization. Understanding these features can allow researchers to elucidate the biochemical mechanisms by which lipid–lipid and/or lipid–protein interactions take place within the conditions of study. Herein, we provide an overview of essential methods for the examination of lipids, including extraction methods, chromatographic techniques and approaches for mass spectrometric analysis.

Keywords: phospholipids, chromatography, extraction, mass spectrometry, lipidomics

Introduction

Lipids make up a diverse subset of biomolecules that can be grouped into the following categories: fatty acids, glycerolipids, glycerophospholipids, sphingolipids, sterol lipids, prenol lipids, saccharolipids and polyketides (Fahy et al., 2009). They are responsible for mediating a variety of structural and functional properties, and reside predominantly in cell membranes as the primary constituents of the bilayer. Lipid bilayers also house various embedded proteins that contribute to the cell membrane functionality. Lipids are not only are essential for cellular architecture, but are involved in processes that modulate cellular function such as trafficking, regulation of membrane proteins and subcellular compartmentalization. Of the categories mentioned above, phospholipids (PLs) are one of the most abundant constituents of biological membranes and play important roles in cellular processes like transmembrane signaling and structural dynamics. The major PL classes ( Fig. 1 ) are: (1) phosphatidylcholines (PC); (2) phosphatidylethanolamines (PE); (3) phosphatidylinositols (PI); (4) phosphatidylserines (PS); (5) phosphatidylglycerols (PG); and (6) phosphatidic acids (PA). Of these, (1)–(5) are predominantly found in the membranes of mammalian cells. These can often exist as phospholipid variants, with a diverse array of alkyl chains, such as sphingolipids, plasmalogens, glycerol diesters and poly-phosphorylated species. PLs are amphipathic molecules that can be distinguished by two hydrophobic fatty acyl molecules esterified at the sn-1 and sn-2 positions of glycerol and a polar head group linked by a phosphate residue at the sn-3 position. PL classes differ in terms of size, shape, charge and chemical composition, which gives rise to an asymmetric distribution within the membrane. The chemical and physical properties of membranes are greatly determined by the PL composition. PLs can also stabilize membrane-bound proteins and serve as cofactors for enzymatic reactions. The generation of first and second messengers, for example, inositol trisphosphate, phosphatidylinositol 4,5-bisphosphate and platelet-activating factorm, are responsible for regulating PL metabolism, secretion, cellular architecture and membrane fusion. Although the structural building blocks for lipid molecules are not very complex, they have the potential to generate almost 100,000 different molecular species (van Meer, 2005; Yetukuri et al., 2008). This lipid diversity is regulated and synthesized by a considerable part of the genome, and the role of this compositional complexity remains broadly defined.

An external file that holds a picture, illustration, etc. Object name is nihms-1736513-f0001.jpg

Structures of phospholipid classes.

The complete profile of lipid species present in a cell, organelle or tissue refers to the lipidome, whereas the study of lipid profiles within biological systems can be referred to as lipidomics (Gross and Han, 2011). Lipidomics seeks to identify lipid alterations within a target system, characterize molecular species and determine the roles of genes and proteins involved in lipid metabolism and lipid-mediated signaling (Gross and Han, 2011; Wenk, 2010). Identifying the biological significance of lipid alterations can provide insight into processes that regulate cellular homeostasis in health and disease states. Although lipids stand out among cellular metabolites in the sheer number of unique species, this class of biomolecules remained in the shadow of the ongoing ‘omics’ revolution for a long time. The chemical and structural variety of lipids makes analysis using a single experimental approach quite challenging (Shevchenko and Simons, 2010; Wenk, 2010). Research in the field relies on the use of multiple techniques to detect and quantify components of cellular lipidomes as well as determine structural features and cellular organization. Understanding these features can allow researchers to elucidate the biochemical mechanisms by which lipid–lipid, lipid–protein interactions take place within the conditions of the study. Lipidomics studies, both untargeted and targeted, use similar experimental protocols that have been heavily bolstered by recent developments in modern mass spectrometry (MS)-based analytical platforms ( Fig. 2 ). Lipidomics is a rapidly expanding field of research, which has emerged as a valuable approach to understanding lipid biology in the biosciences.

An external file that holds a picture, illustration, etc. Object name is nihms-1736513-f0002.jpg

Herein, we will provide an overview of essential methods for the analysis of lipids, including extraction methods, chromatographic techniques and approaches for mass spectrometric analysis.

Extraction techniques

The complexity of biological samples, such as tissues, cells and body fluids, often requires optimization of techniques for sample preparation. For the extraction and analysis of lipids, there are two major challenges to overcome, which are extraction efficiency and complete removal of nonlipid contents. By optimizing sample preparation, it is possible to increase throughput and analyses reproducibility. This section will discuss organic solvent extraction and solid-phase extraction (SPE), which have been used extensively for lipid sample preparation. Figure 3 provides a summary of these extraction techniques.

An external file that holds a picture, illustration, etc. Object name is nihms-1736513-f0003.jpg

Overall applications of extraction techniques on lipids research. *pH values are approximated, pH adjustment depends on analytes

Organic solvent extraction

Proper organic solvent extraction relies heavily on the selection of lipid-soluble solvents. For polar lipids containing both hydrophilic and hydrophobic groups, appropriate organic solvents include chloroform and methanol. Alkane solvents are well suited for extraction of nonpolar lipids lacking hydrophilic groups, such as triacyglycerols and sterols. Lipid solubility can be quantified directly using pure lipid standards; however, predicting or measuring extraction efficiencies is often a challenge when extracting lipids from biological samples. This is due mainly to the strong interactions between lipids and cell biopolymers such as proteins and polysaccharides. Extraction solvents should be selected carefully in order to disrupt these molecular associations, with a balance of both polar and nonpolar characteristics. Polar solvents such as methanol have high dielectric constants that are able to access regions of ion–dipole interactions and hydrogen bonds, and can interrupt such associations.

The Folch method, published in 1957, is the most commonly used lipid extraction technique (Folch et al., 1957). It uses a mixture of chloroform and methanol in a 2:1 ratio, which can simultaneously overcome both hydrophobic and polar interactions between lipids and biopolymers. A wash step is incorporated following extraction to remove nonlipid components using small volumes of water. It is critical that the ratio of chloroform–methanol–water is maintained at 8:4:3 to prevent the loss of polar lipids as a result of excess water. This method yields higher lipid extraction efficiency than any other single solvent method.

The Bligh and Dyer method was introduced as a variation of the Folch method (Bligh and Dyer, 1959), which incorporated water present within samples into the solvent system and made the extraction procedure convenient and economical. Generally, the Folch method is used for the extraction of lipids from solid tissue whereas the Bligh–Dyer method is advantageous for biological fluids (Schiller et al., 2004).

Charged, polar lipids such as glycerophospholipids are able to bind to various biopolymers through ionic interactions that cannot be easily disrupted by polar organic solvents. In such cases, pH adjustments to the aqueous medium prior to extraction can be beneficial for achieving quantitative extraction. Acidification is an effective way to increase extraction efficiency. The addition of acid can convert negatively charged ionized molecules (lipids or biopolymers) to non-ionized forms, interrupting ionic interactions along with increasing lipid hydrophobicity. This was demonstrated in a study where the extraction of polar lipids from M. thermoautotrophicum cells was six times greater by replacing the water in the Bligh–Dyer solvent system with 5% trichloroacetic acid (Nishihara and Yosuke, 1987). We also determined that acidified extraction is not only beneficial for maximal recovery, but can also increase the ionization efficiency of lipids in mass spectrometric analysis ( Fig. 4 ). However, acidification of extraction procedures must be used cautiously, where the pH range is maintained at 2–4. Ester bonds are vulnerable to acid, and hydrolysis can take place after long exposures to concentrated acid, resulting in the loss of lipids. To overcome this phenomenon, Nishihara and Yosuke (1987) used 5% trichloroacetic acid in the place of hydrochloric acid (2 m ).

An external file that holds a picture, illustration, etc. Object name is nihms-1736513-f0004.jpg

Effect of acidification on the signal intensity of DPPC, DSPC, DSPE, DSPA, DSPS, and DSPG after acidified Bligh–Dyer (BD) extraction. Six different phospholipids were prepared, extracted using neutral or acidified BD extraction, then analyzed using ESI-MS. The intensity changes after acidification were shown via comparing to control. The conventional BD extraction was set as control and made 100%. Data are presented as mean ± SEM (n = 3).

Temperature is another feature that should be controlled. Low temperatures are essential for large sample sizes undergoing acidified extraction and quantitation. Our laboratory, along with many others, showed that reduced temperatures reduce degradation and improve lipid stability ( Fig. 5 ). The control of both pH and temperature can prevent the occurrence or reduce the rate of hydrolysis. It is important to note that acidified extraction methods are not suitable for the long-term storage of samples, thus requiring analysis immediately following extraction.

An external file that holds a picture, illustration, etc. Object name is nihms-1736513-f0005.jpg

Effect of acidification on stability of phospholipids after acidified BD extraction. Six different phospholipids were prepared, extracted using neutral or acidified BD extraction. The extracts were allowed to incubate at either 20 or 4°C for 0 or 20 h prior to analysis using ESI-MS. With acidified BD extraction, a varying extent of degradation was observed with all phospholipids except DSPS at 20°C (A). At 4°C (B), only phosphatidylcholines (PCs) show significant degradation. No significant degradation was observed in samples extracted using conventional BD extraction. The time point of 0 h was set as a control with the value being set at 100%. Data are presented as mean ± SEM (n = 3).

A liquid–liquid extraction method utilizing methyl tert-butyl ether (MTBE)/methanol was developed recently and simplified the handling of samples in comparison to the Folch and Bligh–Dyer methods (Matyash et al., 2008). In this method, the low density of MTBE causes the lipid-containing organic phase to form the upper layer during liquid-phase extraction. In the Folch and Bligh–Dyer methods, the lipid-containing phase forms the lower layer due to the high density of chloroform, which can make lipid layer collection difficult. Also, non-extractable matrices such as denatured proteins can be removed by centrifugation easily since they form a dense pellet at the bottom of the extraction tube instead of in between the upper and lower phases as observed with the Folch and Bligh–Dyer methods. This suggests that the MTBE method yields similar or better recoveries of most major lipid classes compared with Folch or Bligh–Dyer. It can also be used for the simultaneous extraction of lipids and metabolites for metabolic profiling and lipidomic analysis. MTBE extractions can be performed on limited amounts of tissue samples (i.e. 2.5 mg) and are suitable for the handling of clinical specimens (Chen et al., 2013).

Organic solvent extraction, such as chloroform and methanol, has been used widely for lipid research and while there are various advantages, limitations persist. Some of these include labor-intensive and time-consuming procedures such as multiple extractions per sample for optimal recovery. Extraction efficiencies can be inconsistent, especially in the presence of emulsifiers, a common occurrence in complex biological samples. Emulsions can result in the partial or complete loss of complex glycolipids and polar prostaglandins in the aqueous layers (Chen et al., 2013). Further, the need for high volumes of toxic, organic solvents requires researchers to utilize extra preparative measures for safety.

It is important to point out that methanol, mentioned in the methods above, does not typically serve as an extraction reagent for lipids since it is miscible with water. Rather, it is used as a reagent that disrupts the interaction between lipids and biopolymers. Similar solvents would be ethanol, 1-propanol, 2-propanol and n-butanol. While ethanol may offer a similar disruption effect as methanol, 1- and 2-propanol may be weaker owing to the larger hydrophobic moiety. n-Butanol is the weakest in disruption among these four solvents, but it is only partially miscible with water, and can sometimes be used to extract lipids without the aid of other organic solvents. Altering solvents with the goal of providing a cleaner matrix is usually more applicable when the analyte is fully understood. In this case, the solvents can be chosen accordingly to inhibit the extraction of undesirable lipids and nonlipid content. However, this is not always the case in most lipid research, especially in lipidomics where hundreds, if not thousands, of lipids are extracted at once. Generally, a recommended approach would be to extract total lipids as much as possible, then further clean the sample using SPE if necessary. In such a scenario, methanol is usually the best choice.

Solid-phase extraction

Solid-phase extraction was first introduced in the mid-1970s as a method for quick and efficient sample preparation for lipid analysis (Thurman and Mills, 1998). This technique uses principles similar to those in liquid chromatography where lipids in hydrophilic media are retained on the SPE column, while the nonlipid impurities are allowed to pass through. Lipids are then eluted and collected using organic solvents with lower polarities. SPE is a useful method for the isolation and purification of targeted lipids along with the enrichment of minor lipid species. The cartridges come in a variety of formats for the handling of different lipids, matrices, volumes and sample concentrations. Some of these include the syringe barrel, large volume capacity barrel, 96-well format and pipette tip format. SPE cartridges, like columns used in high-performance liquid chromatography (HPLC), can be classified as reversed phase, normal phase and ion exchange. SPE is powerful for a broad range of applications and when combined with a variety of elution procedures, is useful for total lipid purification as well as class separation.

With reversed-phase SPE (C18) cartridges, crude lipid extracts obtained from the Folch or Bligh–Dyer method can be diluted with water/methanol, and then loaded on the activated SPE cartridge. As the polarity of the solvent is increased, lipids remain bound to the column through hydrophobic interactions while water-soluble impurities can pass through. The remaining lipids can be collected by elution using chloroform–methanol (1:2, v/v). Alternatively, a two-step elution can permit two fractions to be collected. This would require the first elution to be performed with methanol–water (12:1, v/v), and the second elution using chloroform–methanol (1:2, v/v). In doing so, the first fraction contains gangliosides, phosphatidylserine, phosphatidylinositol, phosphatidic acid and sulfatides, while the second fraction contains all phospholipids, cerebrosides and cholesterol (Kyrklund, 1987).

Normal-phase SPE bind lipids via polar interactions, such as hydrogen-bonding and ion-dipole forces, and can used to separate polar lipids from nonpolar lipids that lack polar functional groups. The cartridges available for normal-phase SPE include amino- (NH2), cyano- (CN) and silica (Si) phases. Kaluzny et al. (1985) demonstrated that aminopropyl (NH2) normal-phase SPE can serve as an effective technique to separate different lipid classes including cholesterol, cholesteryl esters, triglycerides, diglycerides, monoglycerides, fatty acids and phospholipids. For example, Kaluzny et al. reported the performance of three NH2-SPE cartridges loaded with crude lipid extracts. The first elution was performed with chloroform–isopropanol (2:1, v/v), ethanol–acetic acid (98:2, v/v) and methanol, which sequentially produced three fractions. The first contained cholesterol, cholesteryl esters, tryglycerides, diglycerides and monoglycerides, which were then loaded onto a second cartridge. The second and third fractions contained fatty acids and phospholipids, respectively. Additional elution steps were carried out sequentially with hexane (100%), hexane–dichloromethane–ethanol (89:10:1, v/v), hexane–ethyl acetate (95:5, v/v), hexane–ethyl acetate (85:15, v/v) and chloroform–methanol (2:1, v/v). This yielded five fractions: (1) cholesterol esters, and later fractions with (3) 90% of cholesterol, (4) diglycerides and (5) monoglycerides. A third cartridge was then able to separate the second fraction (2) into triglycerides and 10% cholesterol. A modified procedure was also developed for separating chlorinated fatty acid methyl esters from the unchlorinated counterparts (Åkesson-Nilsson, 2003).

Ion-exchange SPE, another useful technique for the isolation and separation of lipid species, can be classified into weak or strong cation and anion exchangers. Strong cation exchangers contain negatively charged benzenesulfonic acids or propylsulfonic acids, while weak cation exchangers have carboxylic acids that are charged at high pH ranges and neutral at low pH ranges. Strong anion exchangers possess positively charged quaternary amines, while weak anion exchangers have primary, secondary or tertiary amines that are positively charged at low pH but neutral at high pH. An earlier method used silver ion-exchangers that have silica-based benzenesulfonic acid SPE cartridges, which can be loaded with a solution of silver nitrate in acetonitrile–water (10:1, v/v) for conversion to the ionic form of silver. The elution scheme for isolating fractions from these ion-exchange cartridges uses varying ratios of dichloromethane, acetone and acetonitrile to separate saturated monoenes, dienes, trienes, tetraenes, pentaenes, hexaenes-fatty acid methyl ester derivatives (Christie, 1989). A similar study was performed to achieve separation of saturated, unsaturated and trans-unsaturated fatty acids (Goto et al., 2012). Ion-exchange SPE cartridges are used widely by researchers for the removal of lipids from analytes of interest (Shen et al., 2005; Yoon et al., 2015). Method development can be optimized easily for separating positively or negatively charged lipids, and is especially appropriate for phospholipids. Anionic phospholipids such as phosphatidic acid and phosphatidylserine are negatively charged at high pH ranges, permitting them to be retained on strong anion-exchange SPE cartridges, allowing cationic phospholipids (neutral at high pH ranges) to pass through. Eluting solvent pH is easily adjusted to

SPE is not only an effective tool for analysis of crude lipid extracts, but can be also applied directly to some biofluid samples such as serum, urine and cerebrospinal fluid. It is important to note that acidification is an essential step prior to sample loading onto SPE cartridges in order to increase lipid retention. Further, low loading and reduced flow rates should be employed for maximal retention. Online SPE liquid chromatography (SPC-LC) is the preferred method when compared with manual SPE (offline). It is highly reproducible, less time consuming and labor intensive, and reduces the potential of exposure to potentially hazardous biological samples. Although online SPE has several advantages including high-throughput features for large sample sizes, clinical research, and diagnostics, it has higher instrumentation costs (de Jong et al., 2007).

Chromatographic methods

One method employed for many lipidomic studies involves the direct infusion of whole lipid extracts into ESI sources. (Han and Gross, 2005b; Han et al., 2005, 2006; Hsu et al., 1998; Koulman et al., 2007; Schwudke et al., 2006). This is referred to as a ‘shotgun’ approach (Han and Gross, 2005a) and involves no chromatographic separation of lipid classes prior to infusion. This platform permits analysis of the lipidome directly from crude lipid extracts where lipids undergo intrasource separation and can be analyzed using precursor ion and neutral loss scans to identify key lipid fragments. While shotgun lipidomics is simple, high-throughput and quick, requiring short data acquisition times, a significant disadvantage of this approach is that many compounds, such as major phospholipid molecular species and their counter-ions, can compete for ionization upon simultaneous infusion into the ESI source and result in ion suppression (Roberts et al., 2008; Wolf and Quinn, 2008). As a result of this competition, ion-suppression can interfere with the detection of minor species within a sample matrix. Detection and sensitivity can also be limited by the presence of isobaric species (Ivanova et al., 2009). Introducing a preliminary separation step prior to infusion, such as HPLC, high-performance thin-layer chromatography (HP-TLC) or gas chromatography (GC), can minimize suppression, allowing compounds to be resolved sequentially with greater ionization yields and increased sensitivity (Petković et al., 2001; Roberts et al., 2008; Wenk et al., 2003; Wolf and Quinn 2008).

Gas chromatography can be used for phospholipid analysis; however, this is not an optimal choice given that separation is dependent on analyte volatility (Axelsen and Murphy, 2010; Buyer and Sasser, 2012). For this technique, phospholipids can be hydrolyzed to diacyglycerols with phospholipase C and derivatized for GC analysis (Tserng and Griffin, 2003). A further drawback is that these analyses require high column temperatures that can result in sample degradation, compromised sensitivity and data quality. Capillary columns are commonly used and provide chromatographic resolution as well as reproducible retention times (Dunn et al., 2011). Although there is a wide range of stationary phases available for GC, methyl-phenyl columns are typically used, and flame ionization detectors serve as the most common detection method (Dunn et al., 2011).

Thin-layer chromatography (TLC) was the earliest and widely established chromatographic method used for lipid assessment that continues to be employed today (Fuchs et al., 2007; Touchstone, 1995; Weerheim et al., 2002). Recent advancements in the application of TLC and HP-TLC have resulted in greater separation efficiencies during lipid analysis (Carrasco-Pancorbo et al., 2009). TLC has proven to be a highly effective and versatile technique for phospholipid separation (Touchstone, 1995). The majority of TLC-based phospholipid separations are performed using a silica gel stationary phase, in conjunction with organic solvents such as chloroform, methanol, water and modifiers as the mobile phase (Handloser et al., 2008). Separation takes place on layers of silica gel adsorbent on glass plates where lipid samples are applied as discrete spots. Lipid samples travel in the mobile phase at different rates based on their affinity for the silica adsorbent. One-dimensional TLC is useful for simple mixtures, while two-dimensional TLC (2D-TLC) yields better resolution for complex lipid mixtures. HP-TLC is commonly coupled with densitometric quantification and various detection reagents can be used to identify resolved lipid classes (Grizard et al., 2000; Helmy, 2004; Moe et al., 2004; Sommerer et al., 2004; Zhong et al., 2000). TLC and HP-TLC are advantageous because of simplicity, high resolving power, and affordability, but are limited by low resolution, sensitivity and lipid recovery (Carrasco-Pancorbo et al., 2009; Cartwright, 1993). Although TLC is a quick method with no sample carryover as each analyte has a new stationary phase, liquid chromatography typically gives better separation (Touchstone, 1995) and may be coupled to a variety of detectors.

High-performance liquid chromatography, in comparison to other chromatographic methods, is the most popular method and has very broad applications in lipid analysis. This is possibly due to the ability to utilize multiple HPLC methodologies for isolation and analysis of phospholipids. Partition chromatography is defined by two polarity modes: normal-phase liquid chromatography (NP-LC) and reversed-phase liquid chromatography (RP-LC) (Carrasco-Pancorbo et al., 2009). Generally, NP-LC separates lipid classes, while RP-LC separates based on fatty-acyl composition (Lin, 2007). For this reason, NP-LC is useful for separating phospholipids with differing head groups, while RP-LC can separate phospholipids of the same class. Both normal-phase and reversed-phase based separation methods have been used for the separation of lipid classes; however, complete class separation has not been shown (Castro-Perez et al., 2010; Peterson and Cummings, 2006). While the mobile phases selected for HPLC vary depending on the column of choice, typical solvents used for chromatographic elution include alcohols, such as methanol and 2-propanol, acetonitrile, hexane, chloroform and/or water (Uran et al., 2001). For subsequent mass spectrometric analyses, acetic or formic acid are added along with an amino-base (ammonia, methylamine, diisopropylamine and piperidine) in order to facilitate ion-pairing in both negative and positive ionization modes (Wolf and Quinn, 2008).

Normal-phase methods are used in HPLC to accomplish initial separation of phospholipid classes through either gradient or isocratic elution (Hermansson et al., 2005; Houjou et al., 2005; Ivanova et al., 2007; Taguchi et al., 2000). In NP chromatography, phospholipids elute in order from the most hydrophobic to the most hydrophilic using a polar stationary phase and a less polar mobile phase (Houjou et al., 2005). Elution patterns are based largely on the polar properties of the phospholipid head group. During instances where head groups possess similar polarities, separation is accomplished based on differences in their backbone. Commonly used NP stationary phases include silica, alumina and cyano columns (Meyer, 1998; Snyder et al., 1997). Silica is the most common of the nonbonded phases and yields greater selectivity; however, this method can be limited by retention time reproducibility across runs owing to water adsorption (Meyer, 1998; Snyder et al., 1997). Alumina is not as common because of its low theoretical plate number, as well as retention time variability and poor sample recovery. Cyano stationary phases are quite stable and can also be used for phospholipid analysis. Selection of solvents for NP chromatography requires consideration of several factors, including solvent strength, localization, basicity and cutoffs for UV detection (Meyer, 1998; Snyder et al., 1997). Disadvantages to using normal phases include lengthy elution and equilibration times, resulting in low throughput. Chloroform and hexane are commonly used mobile phases, both of which introduce ionization challenges when coupled with MS (Henderson and McIndoe, 2006). A more recently identified approach that can be used to retain amphiphilic compounds such as phospholipids is hydrophilic interaction liquid chromatography (HILIC) (Schwalbe-Herrmann et al., 2010; Zhu et al., 2012). This technique is a combination of a polar stationary phase with a highly organic mobile phase that increases the retention of solutes as the percentage of organic solvent is increased (Zhu et al., 2012). Although HILIC is a variant of NP chromatography, RP solvent systems are frequently used to avoid the issues commonly encountered with conventional normal phase methods. Some of the advantages HILIC presents are lower back pressures and higher sensitivity when coupled with ESI-MS.

Reversed-phase chromatography uses a nonpolar stationary phase and a polar mobile phase and is based on lipophilicity, where lipids within the same class separate according to carbon chain length and quantity of double bonds (Perona and Ruiz-Gutierrez, 2003; Pietiläinen et al., 2007). C18, C8 and octadecylsilyl RP columns have been employed using eluting solvents such as methanol, isopropanol, acetonitrile, hexane and chloroform (Medina-Gomez et al., 2007; Rainville et al., 2007; Wolf and Quinn, 2008). When using these columns, hydrophobic C18 groups interact with the hydrophobic fatty acid chains of phospholipids (Zhai and Reilly, 2002). As a result, phospholipids with longer fatty acid chains possess greater solute hydrophobicity, and retention times are decreased as the number of double bonds on fatty acid chains is increased (Zhai and Reilly, 2002). Resolution following separation and speed optimization can be implemented with higher column temperatures with or without gradients, along with column particle sizes

Detectors

The most common chromatographic detection methods include refractive index detection (RID), evaporative light-scattering detection (ELSD), electrochemical detection, suppressed conductivity detection and charged aerosol detection (Carrasco-Pancorbo et al., 2009). ELSD utilizes a universal detector that responds to any analyte different from the mobile phase through continuous monitoring, resulting in minimal background signal. ELSD is compatible with a broad range of solvents as well as gradient elution, although isocratic elution, a feature not permitted by RID, is optimal. Furthermore, unlike ultra-violet (UV) detection, the output signal from ELSD is independent of acyl chain length and degree of saturation (Carrasco-Pancorbo et al., 2009). UV detectors are used very frequently for HPLC, as they are relatively inexpensive and easily accessible. These detectors are sensitive, selective, and are optimal for natural lipids containing conjugated double bonds. While UV detection is widely used for phospholipid analysis (Christie, 1987), fluorescence-based detection is not, since only a few rare lipids possess natural fluorescence. Fluorescence can be useful, however, for analysis of fatty acids following conversion to suitable derivatives. Similarly, infrared (IR) detectors are limited to nonpolar lipids with a narrow window for absorbance detection (Hamilton et al., 1987). Recently, detectors with laser light sources have emerged and exceeded the capabilities of previous technologies. One example is the evaporative laser light scattering detector, which has outperformed ELSD in terms of sensitivity, stability and reproducibility (Carrasco-Pancorbo et al., 2009). Charged aerosol detection, developed only in 2004, has also demonstrated greater sensitivity than ELSD with a broader dynamic range (Eom et al., 2010; Moreau, 2009). Normal-phase chromatography is often coupled to ELSD (Hvattum et al., 2006) or UV detection (Saldanha et al., 2006). These detectors are restricted by the lack of selectivity and choice of mobile phase, making MS the preferred detector for lipidomic studies (Malavolta et al., 2004; Wang et al., 2004).

Mass spectrometry

During MS analysis lipid samples undergo ionization and vaporization upon entering the mass spectrometer, and are sorted by mass to charge ratio (m/z) within the mass analyzer (Griffiths and Wang, 2009). Introduction of crude lipid extracts with no prior separation via direct infusion is called shotgun lipidomics (Han et al., 2005; Schwudke et al., 2007b; Shevchenko and Simons, 2010). The shotgun approach, discussed in detail above, is a rapid and effective way to assess lipid profiles. Although an informative and high-throughput approach, shotgun analyses can often be complicated by ion suppression (Blanksby and Mitchell, 2010), as well as inherent bias towards more abundant and easily ionized lipids (Griffiths and Wang, 2009; Han et al., 2012). The alternative to the shotgun method is incorporation of a chromatographic separation prior to MS analysis, resulting in reduced ion suppression and greater sensitivity (Murphy and Gaskell, 2011). However, ionization conditions and column memory effect, the carryover of sample constituents across analysis, can pose significant challenges. Major lipidomic approaches are either the targeted study of individual lipid classes or their subclasses (Han et al., 2012; Lee et al., 2003), or global, broad spectrum profiling of crude lipid extracts. Unfortunately, global lipidomics often results in complex spectra containing numerous isobaric species, and targeted approaches often encounter low abundances of desired lipid classes. Chromatography can address both of these issues by separating target analytes from complex matrices (Blanksby and Mitchell, 2010).

Crude lipid extracts can also be used for direct identification of lipids based on mass via high-resolution mass spectrometers such as the Fourier transform ion cyclotron resonance and FT-Orbitrap (Schwudke et al., 2007a; Shevchenko and Simons, 2010). This is known as top-down lipidomics and these instruments facilitate rapid scanning and high mass accuracy (Griffiths and Wang, 2009; Han et al., 2005). The top-down approach is primarily used for determining alterations in lipid patterns. For the majority of lipid studies, however, tandem mass spectrometry (MS/MS) is the dominant method (Shevchenko and Simons, 2010). The application of tandem MS experiments is referred to as bottom-up lipidomics, where various scanning options (precursor ion scan, product ion scan, neutral loss scan) are used to generate specific fragment ions (Schuhmann et al., 2011; Shevchenko and Simons, 2010). Selected reaction monitoring or multiple reaction monitoring can be used to maximize sensitivity for specific precursors or fragment mass pairs (Griffiths and Wang, 2009). There have been newer developments using nanospray technologies, which have increased the sensitivity of lipid analysis as well as sample throughput using chip-based nanospray array devices (Ejsing et al., 2009). For example, nano-electropray sources (Wilm and Mann, 1994, 1996; Wilm et al., 1996) are able to allow analysis of picomolar or sub-picomolar levels of lipids (Brügger et al., 1997).

Over the past 40 years, GC-MS coupled with electron ionization (EI) has served as a basis for lipid identification and quantification. Although widely used, limitations with this method persist (Berry, 2004). Throughout the mid-1970s, field ionization (FI) was employed; however, lower and less stable ion currents made this method unpopular (Wood and Lau, 1974). Recently, FI has been used in conjunction with orthogonal acceleration time-of-flight MS. This combination has overcome some of the previous challenges posed by FI (Hejazi et al., 2009). Another earlier method used for the analysis of complex, high molecular weight lipids was fast atom bombardment (FAB) MS. It is important to note that findings from studies conducted using FAB, coupled with tandem MS, have laid the foundation for our understanding of the fragmentation of lipid ionization ( Jensen et al., 1987). However, the drawbacks of FAB, including low sensitivity, matrix ions and source fragmentation, greatly limited analysis and quantitation (Blanksby and Mitchell, 2010). The introduction of electrospray ionization (ESI) MS applied to the analysis of glycerophospholipids addressed many of these limitations, including increasing sensitivity by two orders of magnitude, thereby permitting the detection of more than 50 phospholipid species (Han and Gross, 1994; Kerwin et al., 1994; Kim et al., 1994). ESI allows two approaches for lipidomic studies: shotgun lipidomics and chromatography-coupled MS for phospholipid identification and quantitation. While both approaches possess their strengths, the combination of the two can be the most effective (Blanksby and Mitchell, 2010; Ivanova et al., 2009).

Techniques based on ambient ionization, such as desorption electrospray ionization (DESI), have recently emerged and been applied to lipid analysis (Cooks et al., 2006a; Takats et al., 2004). DESI offers direct sampling from biological tissues and does not require high-vacuum conditions (Wiseman et al., 2005). Rapid evaporative ionization mass spectrometry represents another method for lipid analysis, in which ions are formed from the rapid thermal evaporation of biological tissue from a surgical electrode and then extracted into the MS (Schäfer et al., 2009).

The use of tandem MS techniques, such as parent ion and neutral loss scanning (Hayes and Gross, 1989; Yost and Enke, 1979), in combination with ESI and matrix-assisted laser desorption and ionization (MALDI), has been essential in advancing the field of lipidomics (Blanksby and Mitchell, 2010). Tandem MS with CID is an excellent tool for elucidating lipid structures, as well as enhancing analytical sensitivity in both global and targeted lipidomics (Blanksby and Mitchell, 2010).

Ionization methods

The distinction between ‘hard’ and ‘soft’ ionization MS methods is heavily dependent on the properties of the analyte of interest (Fuchs et al., 2010). Most modern ionization methods are considered to be soft ionization when compared with EI (Chapman, 1995). EI makes use of fast electrons in order to ionize the analyte molecules in the gas phase by the removal of one electron. This method has been used exclusively for decades, mainly because of its suitability for the investigation of small and/or volatile compounds (Gross, 2004). However, EI is not very effective for analyzing larger molecules with low volatilities. While detection of phospholipid molecular ions is possible using EI, the abundance of fragment ions makes it difficult to analyze complex mixtures (Klein, 1971). For this reason, EI-MS is now used for assessing free fatty acids in lipid samples. Chemical ionization (CI) is another ionization method used frequently for lipid analyses, and can be used alone or in combination with atmospheric pressure (APCI) (Byrdwell, 2001; Fuchs et al., 2010).

The advent of soft-ionization methods should be considered a milestone in the history of modern mass spectrometry as it enabled analyses of molecules refractive to EI. These methods include ESI and MALDI. ESI and MALDI are the most popular ion sources for lipidomics studies and are commercially available in the majority of MS devices (Fuchs et al., 2010). It is important to note that they are often regarded as competitive methods; however, they should be considered complementary (Fuchs et al., 2010).

Electrospray ionization

The most widely used atmospheric pressure ionization modes are ESI and APCI (Byrdwell, 2001; Peterson and Cummings, 2006). ESI is an appropriate technique for polar compounds including phospholipids (Hunt and Postle, 2006; Kim et al., 2009; Min et al., 2010; Postle 2009; Postle et al., 2007), while APCI is better suited for less polar molecules (Byrdwell and Emken, 1995; Farwanah et al., 2009; Murphy et al., 2011; Xu and Brenna 2007). The soft ionization of ESI is quite effective for polar lipids since they are readily ionized in both negative and positive ion modes, i.e. protonation [M + H] + or deprotonation [M − H] − , resulting in a single intact ion (Blanksby and Mitchell, 2010). ESI-MS performed on samples containing phospholipids generate unique fragment ions, indicating a loss of the polar head group, which can be diagnostic for the presence of individual classes. For example, m/z 184 is indicative of choline-containing phospholipids and can be detected during product ion analysis of protonated choline-containing phospholipid molecular species. Table 1 provides a summary of unique fragments including adducts, in both positive and negative ion mode, which can be used for phospholipid identification. While saturated and monounsaturated fatty acids ionize well in the negative ion mode, it can be difficult to detect fragment ions. Our approach for detection and MS/MS quantification is to utilize precursor ion scanning as the product ion.

Table 1.

Headgroup fragments for phospholipid fragments

ClassCharacteristic headgroup fragments (m/z)
Positive ion
mode (ESI+)
Negative ion
mode (ESI−)
PA
PC184, 60224
PE141196
PG227
PI223, 241, 259, 297, 315
PS87185